TDLAS Laser Gas Analyzer for Metallurgical Gas Emissions Online Monitoring
The KF200 series laser gas analyzer is developed aiming at industrial on-line analyzing and online environmental monitoring. Based on the semiconductor laser absorption spectroscopy (DLAS) technology, it is developed with features of an integrated design and high level of integration.
There are various types of the KF200 series laser gas analyzer, including in-situ probing type, by-pass type, multi-channel and disc mounted type, etc. Gases like O2, CO, NH3, CO2, CH4, H2O, HC, HF, etc., can all be analyzed. The concentration analyzing of target gases includes the macro-analysis and micro-analysis.
Technical Features:
- The TDLAS technology is adopted for in-situ online gas analyzing;
- Double-proof probe design negates positive pressure purge, with no additional data processing unit, a simple compact structure and high reliability;
- Using high-power lasers, no fiber coupling, suitable for harsh working conditions (such as with excessive dust);
- Using the patented technology of spot light path adjustment, easy for on-site installation.
- Explosion-proof design, friendly on-site installation;
- Auto - calibration and auto-back flushing.
Technical Specifications:
Technical Data |
linearity error |
≤ ±1% F.S. |
Span drift |
≤ ±1% F.S./6 months |
Repeatability |
≤ 1% |
calibration period |
≤ 1 time/6 month |
Explosion-proof Grade |
Ex d IIC T6 |
Protection levels |
IP66 |
Response Time |
Warming-up time |
≤ 15 min |
Response time(T90) |
≤ 1 s |
Interface Signals |
Analog outputs |
2-wire 4-20 mA signal input (Isolated, max. load 750 Ω) |
Relay output |
3-wire relay (24 V,1A) |
Digital Communication |
RS485/RS232/GPRS |
Analog inputs |
2-way 4-20 mA input (temperature-pressure compensation) |
Laser Safety Standard |
GB7247.1-2001 (idt IEC 60825-1:1993) |
Operating Conditions |
Storage Temperature |
-30ºC ~ +60ºC |
Ambient temperature |
-40ºC ~ +80ºC |
EMC |
IEC 6100-4-2, IEC 6100-4-3, IEC 6100-4-4, IEC 6100-4-5,IEC 6100-4-11 |
Gas jet |
0.3 ~ 0.8 MPa industrial nitrogen inlet and purification instrument gases, etc. |
Consumption |
< 20 W |
Power |
24V DC (18-36V DC), 220 V AC |
Gas Detection Limits:
Detection Gas Type |
Detection Limit |
Detection range |
O2 |
0.01% Vol. |
(0-1)%Vol., (0-100)%Vol. |
CO2 |
10 ppm |
(0-1000)ppm,(0-100)%Vol. |
H2S |
20 ppm |
(0-2000) ppm, (0-100)%Vol. |
HCl |
0.1 ppm |
(0-50) ppm,(0-100)%Vol. |
NH3 |
0.1 ppm |
(0-10) ppm, (0-100)%Vol. |
C2H2 |
0.1ppm |
(0-10) ppm, (0-100)%Vol. |
CO |
10 ppm |
(0-1000) ppm, (0-100)%Vol. |
H2O |
0.3 ppm |
(0-50) ppm, (0-100)%Vol. |
HF |
0.02 ppm |
(0-5) ppm, (0-10000) ppm |
HCN |
0.3 ppm |
(0-30) ppm, (0-1)%Vol. |
CH4 |
0.4 ppm |
(0-40) ppm, (0-100)%Vol. |
C2H4 |
0.6 ppm |
(0-60) ppm, (0-100)%Vol. |
Main Process
Under the influence of the jet pump, the target gases are processed through probe filter (filtering out dust), heat tracing (avoid raw condensate production), cooling (for high-temperature applications), and inlet laser analysis module for analyzing and measuring. Close the ball valve, open the calibration valve and then do calibration of the laser analysis module. It ensures the accuracy of the device running. Close the ball valve and open the backflushing valve to ensure the sampling passage unblocked.
The configuration of KF200 laser gas analyzer varies based on different applications. For high-pressure situations, pressure reducing valves should be increased, the jet pump not needed.
Our Services
1. For all our products, we offer a 1-year warranty and life-long maintenance.
2. All inquiries will be replied in 24 hours.
3. We will provide technical support; our engineers will help to solve the problems you met.
4. We can provide OEM and ODM service.
5. Our factory is located in Nanjing city, welcome to visit our factory.
6. All products will be fully checked and well packed before shipment, and the qualification certificate will be provided.
FAQ
Q: Are you trading company or manufacturer?
A: We are manufacturer, specializing in design and manufacturing of gas detector and alarm monitoring system.
Q. How about the Delivery time?
A: Samples will be prepared within 5 days after receiving 100% T/T payment in advance. QTY order will be shipped in 20 days.
Q: What kind of payments does KELISAIKE support?
A: T/T, L/C, Western Union and Cash are all accepted.
Q: Do you charge for the samples?
A: Yes, we do. According to our company policy, we only charge the samples based on EXW price, and we will return the sample fee in the next qty order.
Q. Can you produce according to customers' design?
A: Sure, we are a professional manufacturer, and OEM order is welcome.
>>>Company Profile
Nanjing KELISAIKE Safety Equipment Co., Ltd. is one of the largest safety equipment manufacturers in mainland China, possessing the most complete product range and specifications in the safety equipment industry. Founded in 2004, Nanjing KELISAIKE has three subsidiaries in Beijing, Xi'an and Xinjiang province, and over 30 domestic sales service centers.
Standard products include the K60 series portable single gas detectors, K60-IV series multi-gas detectors, K800 series fixed gas transmitters, K500 series wall-mounted gas detectors, K1000 series gas detector control panel units, KL99 series air breathing apparatuses, etc. Nanjing KELISAIKE is also a factory with rich experience in OEM service, providing professional design and manufacturing of customized products. The company's products are widely used in fields of petroleum, chemical, gas transmission and distribution, warehousing, municipal gas supply, fire fighting, environmental protection, metallurgy, pharmacy, energy and power industry.
As a leading enterprise in technology innovation, Nanjing KELISAIKE is committed to developing core competencies by continuous technology research. The company has a team of professional and technical talents, including more than 10 senior technicians and masters, who master quite many core technologies.
Nanjing KELISAIKE has passed ISO 9001 International Quality System Certification. With the guidance and tools of the standard, Nanjing KELISAIKE cannot only ensure that all the company's products and services consistently meet customer's requirements, but also that the quality of the products and services will be consistently improved.