• Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
  • Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
  • Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
  • Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
  • Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
  • Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs

Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs

After-sales Service: 1year
Warranty: 1year
Brand: Kelisaike
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs pictures & photos
Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
US $30,000-70,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2016

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company

Basic Info.

Customized
Customized
Portable
Non Portable
Certification
CE
Gas
Customized
Type
UV Analyzer
Resonse Time(T90)
Less Than 10s
Power
220VAC/50Hz 100W
Protection Grade
IP42
Sample Gas Input and Output Interface
ø 6 Tube Fittings
Transport Package
Carton
Specification
19"x3Ux320mm
Trademark
KELISAIKE or OEM
Origin
Nanjing, China
HS Code
9027900000
Production Capacity
300PCS/Month

Packaging & Delivery

Package Size
57.00cm * 70.00cm * 32.00cm
Package Gross Weight
20.000kg

Product Description

Stack flue gas monitoring heat tracing CEMS UV Hot-Wet SO2, NOx, O2, CO, CO2 gas analyzer
Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
The analyzer based on UV absorption spectroscopy and chemometric algorithms to measure SO2, NOx, O2, NH3, Cl2, O3, H2S and other gases concentration, with high accuracy, high reliability, fast response time, wide application and other characteristics, the indicators have reached or exceeded similar products, it can be widely used in environmental online monitoring, industrial control, security monitoring and other occasions.

>>>Key Features

Full spectrum measurement and DOAS (Differential Optical Absorption Spectroscopy) algorithm, excelling in accuracy,  repeatability and anti-interference with moisture, dust.

Modular design and no moving parts, higher reliability and easier maintenance.

Pulse Xenon Lamp used as light source with over 10-year lifetime.

The adoption of diode array sensor enables instant spectrum acquisition and rapid response.

>>> Features and Benefits
1. Analyzer uses the following optical technology platform to get the UV absorption spectrum, the technology platform consists of light source, gas chamber, fiber optics and spectroscopy (including the diaphragm, holographic gratings, linear array detector) and other optical components.

2. UV-visible light emitted by the optical window into the gas chamber, is absorbed by the sample gas flowing through the measured gas chamber, carrying the tested sample gas absorbs light through the lens after gathering information coupled into optical fiber through the optical fiber transmission into the spectrometer splitting, sampling, to obtain the absorption spectrum of the gas.

3. Use DOAS technology spectrum analysis, can analyze the concentration of the gas in the relevant component.

>>> Measuring principle

Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs

1) The light source emits ultraviolet beam which transfers to gas cell through optical fiber.

2) After absorption by measuring gas, the light beam transfers through optical fiber to spectrometer.

3) Being dispersed through the grating, and converted into electric signal by the array sensor, a continuous absorption spectrum of measuring gas is thereafter obtained.

>>>Technology Comparison

Item UV Hot-Wet   Method NDIR
Spectral   Range Complete and   continuous absorption spectra obtained through holographic grating and diode   array detection Non Dispersive,   characteristic absorption spectra obtained through band-pass filter
Linear   Response High wavelength   resolution secures linear response band-pass   filtration compromises linear response 
SO2 Loss Hot-wet   prohibits SO2   dissolution Condensation   inevitably causes SO2   loss
Sampling   System Heat tracing.   Requests only dust filtration, simple and no corrosive Cold-dry.   Requests dust filtration, condensation, water removal and corrosion proof
Zero   Calibration Period Long (DOAS   algorithm) Short
Anti-Interference The combination   of complete & continuous absorption spectra, high wavelength resolution,   DAOS algorithm erases interference from dust, moisture and background gases Vulnerable to   moisture interference
Gas Cell Connected by optical fiber,   easy to replace and low maintenance cost Complex to replace and   maintenance
Maintenance    
Reliability No moving parts Moving parts   existed

>>>Technical Specifications
SO2, NOx Analyzer
Technical   Principle UV-DOAS
Installation   type Hot-wet    Extractive
Measurement   Range 0~200ppm,    0~1000ppm, 0~3000ppm
Zero   Drift ≤    ±2%F.S.
Span   Drift ≤    ±2%F.S.
Accuracy ≤    ±1%
Response   Time(T90) ≤    60s
Linearity ≤    ±1%F.S.
O2  Analyzer
Technical   Principle Zirconia/Electrochemical
Measurement   Range 0~25%
Response   Time(T90) ≤    60s
Linearity ≤    ±2%F.S.
CO, CO2  Analyzer
Technical   Principle NDIR
Installation   type Extractive
CO   Measurement Range 0~1000    ppm
CO2   Measurement Range 0~20%
Zero   Drift ≤    ±2%F.S.
Span   Drift ≤    ±2%F.S.
Accuracy ≤    ±1%
Response   Time(T90) ≤    60s
Linearity ≤    ±2%F.S.

Technical Data for UV gas analyzer
Project Indicators
SO2 Detection range Min:0-50ppm,Max:0-100%,
NO Detection range Min:0-50ppm,Max:0-100%,
O2 Detection range 0-25%, Electrochemical or zirconia
Linearity error ≤±1%F.S.
Repeatability ≤1%
Zero drift ≤±1%F.S./ week
Span drift ≤±1%F.S./week
Ambient temperature 5ºC~45ºC
Response time(T90) <60s
Size 19" *3U*320mm
Analog interface 3-way 4-20mA output,2-way 4-20mA output
Data interface 4-way switch input; 8-way relay output
Communication Interface 1-way RS-232,1-way RS-485(Supports Mod-bus protocol)
Power 220VAC/50Hz 100W
Protection grade IP42
Sample gas input and output interface Ø6 Tube Fittings

>>> FAQ
1.How about the Delivery time?
Samples will be prepared  within 15 Days after 100% T/T in advance payment. QTY order will be delivered in 30 days.
2.What kind of payments does KELISAIKE support?
T/T, L/C, Western Union, Cash are accepted.
3.What's the MOQ?
Generally speaking, the MOQ is 5PCS, but we also can provide you samples for quality inspection.
4.Do you charge for the samples?
According to our company policy,we just charge the samples based on EXW price.
5.Can you produce according to customers' design?
Suce, we are professional maunfacturer, OEM is welcome

Stack Flue Gas Analyzer CEMS for Nox So2 O2 CO2 Co Vocs 
Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
Introduction:
WT800-VOCs volatile organic compounds online monitoring system has three basic parts: the volatile organic compounds monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor organic pollutant gases such as methane, the total hydrocarbon, non methane total hydrocarbon, low-carbon aldehyde ketone, benzene series(benzene, toluene, xylene, ethyl benzene, isopropyl benzene) and part of halogenated hydrocarbons, also the parameter such as humidity, temperature, pressure and flow velocity of the flue gas. After dedusting by sampling probe, sampling by heating pipe, dehydration and cooling by two-step condensing, the measured gas is analyzed by the heated gas anal-ysis module (GC-FID). For the situation of high boiling point organic pollutant gas monitoring, it can effectively avoid the absorption loss in the process of sample collection and transmission, alsomake sure the excellent performance and stability in sample collection, analysis, data upload and maintain links.

Technical Features:
·Gas Chromatography method defined as an international standard VOC measurement method;
·Making use of the pneumatic constant temperature complies with regulations and this constant temperature from sampling to probe avoids water interference and reduces sample loss;
·Extremely wide range of measurement;
·Sample directly at the probe;
·Ability to measure hundreds of type of waste gas (e.g. NMHC, BTX and odours), the possibility to continuous extend the range and types of measurement;
·Improving security by using FID and anti-explosion design.

Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs

Application:
Apply to manufacturing industry such as crude processing, textile and dyeing, chemical and pharmaceutical, metal smelting, etc.

Technical Specifications:
 
Project Description
VOCs volatile organic compounds Measuring principle Principles of Gas Chromatography
Measuring components Methane/Non-methane total hydrocarbons, benzene series(benzene toluene ),etc.
Measuring range 0-1000ppm(configurable)
Methane
NMHC
Benzene series
0-1000ppm
0-10000ppm
0-1000ppm
The detection limit Methane 0.1ppm
Repeatability RSD≤3%
Measurement deviation ≤2%FS
Analysis cycle 1.5min
Response time 90s(25m heating pipeline)
Sampling pipeline Heating temperature above 125ºC
 
IPC
6 channels RS232/485
4 USB ports
Windows 7
System software Exhaust gas treatment VOCs online monitoring system
Output Analog output channel
RS485 communication interface
GPRS communication interface
Ethernet communication interface
System status switch output(optional)
Power supply 220VAC/50Hz 2kW(host part, excluding heating pipe, air compressor)
Cabinet size 600mmx900mm×2055m
Cabinet temperature (5-35)ºC
Cabinet humidity (20%-90%)R
 
Detector Gas action Gas name Purity
FID Carrier gas He or N2 Not less than99.999%
TCD Carrier gas He,H2or N2 Not less than99.999%
ECD Carrier gas N2 Not less than99.999%(deoxidation)
FPD Carrier gas He or N2 Not less than99.999%
  Tail blowing He or N2 Not less than99.999%
  Combustion gas H2 Not less than99.999%
  Auxiliary gas Air Clean and dry as much as possible

Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs pictures & photos
Stack Flue Gas Monitoring System Heat Tracing Cems UV Hot Wet Analyzer for So2 Nox O2 Co CO2 Vocs
US $30,000-70,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2016

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
OEM/ODM Availability
Yes