Powered Air Purifying Respirator Papr Kl99 Kelisaike

Product Details
Customization: Available
Application: Professional Equipment
Certification: CE, ISO
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
OEM/ODM Availability
Yes
  • Powered Air Purifying Respirator Papr Kl99 Kelisaike
  • Powered Air Purifying Respirator Papr Kl99 Kelisaike
  • Powered Air Purifying Respirator Papr Kl99 Kelisaike
  • Powered Air Purifying Respirator Papr Kl99 Kelisaike
  • Powered Air Purifying Respirator Papr Kl99 Kelisaike
  • Powered Air Purifying Respirator Papr Kl99 Kelisaike
Find Similar Products

Basic Info.

Model NO.
KL99-PAPR
Material
Kevlar or Nomex
Suitable for
Adult
Type
Air Breathing Apparatus
Using Field
Land, Air
Function
Air Breathing Apparatus Papr
Battery
12V/3400mAh Chargeable Li-ion Battery
Charging Cycle Times
200 Times
Working Hours at Full Power
>4 Hours
Air Output Gear
145L/Min
Acoustic Sound Level
<50dB
Weight
<850g
Alarm
Automatic Detection and Warning O
Transport Package
Carton
Specification
60*45*20
Origin
Nanjing, China
HS Code
90200000
Production Capacity
1000sets

Product Description

Powered Air Purifying Respirator PAPR

Product Description
The KL99-PAPR is a battery-powered fan that together with a filter and an approved head top, is included in the fan-assisted respiratory protective device systems. This applies particularly to work that is hard, warm or of long duration. The human interface may consist of a hood, face shield, half mask or full face mask. The fan is equipped with a filter, and the filtered air is fed through a hose to the human interface. The pressure then generated prevents surrounding pollutants from penetrating into the mask. Power blower unit provides filtered air for the widest range of industrial applications as diverse as industrial welding, agriculture and waste disposal.

Powered Air Purifying Respirator Papr Kl99 Kelisaike

Introduction
•   Starting up
Long press the power button 3s to boot, enter the low-end working state
•   Power off
Press the power button for 3 consecutive times to turn off, stop working, and all indicator lights are off
•   Indicator light
There are 4 indicator lights in total, 3 of which are white and green indicating the power level
•   Electric quantity
When the battery is fully charged, the three-digit indicator light (white) is fully illuminated, and the indicator lights are extinguished one by one as the usage time increases. When the remaining 1 white light flashes, please pay attention to charging.
•   Battery charging
When charging, the first white light flashes, the first grid is long after 1 grid is filled, the second grid white light is flashing, and so on, and finally the three grid white lights are on, indicating that the battery is fully charged.


Powered Air Purifying Respirator Papr Kl99 Kelisaike


Optional Communication Mask System
This product is used as an auxiliary part of communication with the mask. This product has a unique design, which can effectively amplify the voice of the person wearing the mask, keep the communication smooth, and ensure the clear and sonorous sound quality . At the same time, it can also be used in conjunction with the intelligent digital electronic pressure gauge to display the information of the remaining amount of gas in the cylinder. The overall design of the product is exquisite, and the mask is easy to install and operate.

Powered Air Purifying Respirator Papr Kl99 Kelisaike


Technical Parameter
 

Technical Parameter

Battery

12V/3400mAh chargeable Li-ion Battery

Working hours at full power

>4 hours

Charging Cycle Times

>200 times

Charging Cycle Times

>200 times

Air output gear

145L/min

Acoustic sound level

<50dB

Size

185(length) x 162(width) x 101(height)

Weight

<850g

Filter

With three replaceable filters

Green LED power indicator

Fast lock and unlock structure

Automatic detection and warning of low voltage

Normal use after 7J energy shock

Heat-resistant and cold-resistant

It can be normally used after being stored under the concentration of 5000ppm hydrogen tetroxide steam for five hours


Company Information
Powered Air Purifying Respirator Papr Kl99 Kelisaike
Our Services

1.The inquiry and question will be replied within12hours
2.High quality with competitive price

3.Good after sales service
4.Accept OEM
5.One of the most professional safety equipment manufacture with a very good and trained team


FAQ

1.How about the Delivery time?

Samples will be prepared  within 5 Days after 100% T/T in advance payment. QTY order will be delivered in 20days.

2.What kind of payments does jenor support?

T/T, L/C, Western Union, Paypal & Cash are accepted.

3.What's the MOQ?

Generally speaking, the MOQ is 10PCS, but we also can provide you samples for quality inspection.

4.Do you charge for the samples?

According to our company policy,we just charge the samples based on EXW price.and we will return the samples fee during the next qty order.

5.Can you produce aocording to customers' design?

Suce, we are professional manufacturer and OEM services is welcome!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier