2022 New Design Rn55 Radon Gas Detector

Product Details
Customization: Available
Transport Package: Carton
Specification: 150g
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
OEM/ODM Availability
Yes
  • 2022 New Design Rn55 Radon Gas Detector
  • 2022 New Design Rn55 Radon Gas Detector
  • 2022 New Design Rn55 Radon Gas Detector
  • 2022 New Design Rn55 Radon Gas Detector
  • 2022 New Design Rn55 Radon Gas Detector
  • 2022 New Design Rn55 Radon Gas Detector
Find Similar Products

Basic Info.

Model NO.
RN55
Origin
Nanjing, China
Production Capacity
1000sets Per Month

Packaging & Delivery

Package Size
125.00cm * 70.00cm * 25.00cm
Package Gross Weight
0.150kg

Product Description

2022 New Design RN55 Radon Gas Detector


Product Description

2022 New Design Rn55 Radon Gas Detector
Introduction
Radon is a naturally occurring radioactive gas released from the ground that can enter buildings and accumulate to high levels. As long-term exposure to elevated levels of radon can cause lung cancer, it is important to know whether a building's occupants are being exposed to unacceptably high levels of radon.
Radon monitor are pleased to offer our customers a wide range of options for testing buildings for radon, with the latest of these being the digital radon monitor.


2022 New Design Rn55 Radon Gas Detector
2022 New Design Rn55 Radon Gas Detector


Feature

Radon monitor provides a digital readout of the levels on an easy-to-read screen. The device displays the average radon level over the last 24 hours, 7 days and 365 days.

Accurate readings are produced after 24 hours of operation, and there is a reset button that can be used should you wish to move the device to a different room or property and restart the monitoring.

The slim, lightweight design coupled with the rechargeable lithium battery operation enables the device to be placed wherever it is required with no cables needed. 

Ideal for use in homes or workplaces, the radon monitor is an affordable way of monitoring radon levels to ensure a healthy environment.
 

1.  Indicator for battery level. The batteries need to be recharged when it indicate low battery.

2. 'LONG TERM AVERAGE' long term average measurement mode.

3. 'SHORT TERM AVERAGE', short term average measurement mode.

4.  Measurement period for short term average. Alternates between 1 and 7 days.

5. 'RUN' indicator for measurement. The unit is active when this is flashing. It indicate "STOP" when unit is stop and indicate"ERROR" when unit is failed.

6. 'power' button for resetting and turn on/off THE UNIT.

 

-Press the button continuously for 3 times when a new measurement period starts. Deletes all stored data from earlier measurement.

-Keep pressing button for more than 6 seconds to turn on the unit... Also you can press button for more than 6 seconds to turn off the unit

 

7. The coefficient of injury +1 when short term average increase each 25BQ/M3, total 10, it mean Max measurement range will be 250BQ/M3.

And the 'WARNING' indicator will flash when more than 5 (100bq/m3), also the flash frequency become more and more fast with the increasing coefficient of injury.

 

Specifications

Detecting Technology Passive radon diffusion chamber
Sensor Alpha spectrometry sensor
Battery 3AAA alkaline Battery ( LR03 )2 years battery life
Accuracy/Precision 7 days <10%
@200Bq/M3  (5.4pCi/L)-Typical 2 months <5
Measurement range 0-9999Bq/M3 (or 0-500pCi/L)
Operation environment Temperature: 4ºC to +40 ºC   Relative humidity <85%
Dimensions L125*W70*H25mm
Weight 150g 

 

Safety

Contact the seller if the product requires service or repairs.
The front or back cover must not be opened
Avoid subjecting the unit to shock,impact,pressure,vibrations,dust and moistrue.
The unit must not be exposed to direct sunlight for extended periods.
Use only AAA alkaline batteries ( LR03 ).
Batteries must not be exposed to flame or other high heat sources.
Battery terminals shall not be touched and kept free of dust, sand and liq

 

Getting started

1.Firstly, Pull out the plastic tab by the battery lid at the back of the Monitor.
2.Then the display shows 'CAL' (calibration) and counts up to minimum 50. The monitor self-test in this phase. Duration time less than 30 sec.
3.The LCD screen shows up to 4 flashing dashes indicating the time left until radon levels are shown. In this phase, data is obtained for an initial radon level calculation. The phase duration depends on radon levels,but typically ranges from 6 to 24 hours. The indicator at the top left of the screen flashes when the monitor is active.
4.Place the monitor in living areas (e.g.,bed room and living room) and in places deemed representative of the air breathed in each living area.