Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser

Product Details
Customization: Available
Brand: Kelisaike
Customized: Customized
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
OEM/ODM Availability
Yes
  • Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
  • Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
  • Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
  • Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
  • Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
  • Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
Find Similar Products

Basic Info.

Model NO.
KF100-CEMS
Portable
Non Portable
Certification
CE
Gas
Nox
Type
UV Analyzer
So2 Detection Range
0 - 20 Ppm, 0 - 3000ppm
Nox Detection Range
0 - 20 Ppm, 0 - 3000ppm
O2 Detection Range
0 - 25%
Co Detection Range
0-1000ppm
CO2 Detection Range
0-20%Vol
Dust Detection Range
0 - 500mg/M3
Temperature
0 - 400ºC
Pressure
-10kpa~10kpa
Flow
0 - 40m/S
Humidity
0 - 40%Vol
Signal Transmission
RS485,4-20mA
Sysrtem Software
Window7 Linux
Power
220 V AC/50 Hz 4000 W
Transport Package
Wooden Box
Specification
200*800*600mm
Trademark
KELISAIKE
Origin
China
HS Code
9027100090
Production Capacity
500

Product Description


 Continuous Emission Monitoring System SO2 NOx O2 NO NO2 with Ultraviolet UV Gas Analysers
Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
Introduction
:

The CEMS-1000 flue gas emission continuous monitoring system (CEMS) is composed of four basic parts: the smoke and dust monitoring subsystem, the gaseous pollutant monitoring subsystem, the flue gas parameter monitoring subsystem, the system control and the data acquisition and processing subsystem. It can monitor SO2, NOx, O2, dust, temperature, pressure, flow rate, humidity and other parameters in the gas, and can also expand the monitoring of HCl, HF, CO, CO2,NO2 and other parameters for specific occasions. The measured gas passes through the sampling probe to remove dust, heat tracing tube sampling, multi-stage filtration, secondary condensation to quickly remove water and cool down, and enter the micro heat tracing gas analysis module (DOAS and TDLAS technology) for analysis and measurement. The use of dry measurement effectively solves the technical problems of large fluctuations in data measurement caused by large humidity changes such as waste incineration.
Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser


Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
Technical Features:
The secondary condensation quickly removes water and cools, reduces air and water contact time, and reduces SO2 loss; the analyzer adopts micro-heating technology to reduce the maintenance period of the measuring pool; fast loop sampling pump sampling, fast response time; multi-stage filtration and water removal, Dust removal, high reliability; can achieve full calibration.


Application:

Coal-fired power plants, waste-to-energy power plants, cement plants, glass plants, lime plants, ceramic plants, sintering, coke ovens, desulfurization processes, denitrification processes and other exhaust emission monitoring and process control.


Technical Specifications:
Project Indicators
SO2 Detection range 0 - 20 ppm, 0 - 3000ppm
NOx Detection range 0 - 20 ppm, 0 - 3000ppm
O2 Detection range 0 - 25%, Electrochemical or zirconia
CO Detection range (Optional) 0-1000ppm
CO2 Detection range(Optional) 0-20%Vol
Dust Detection range 0 - 20mg/m3, 0 - 500mg/m3
Temperature 0 - 400ºC
Pressure -10kPa~+10kPa
Flow 0 - 40m/s
Humidity 0 - 40%Vol
Ambient temperature 5ºC ~ 45ºC
Ambient Humidity 0~95%RH
Sample gas flow 0.3-1.L/min
Signal transmission RS485,4-20mA
Size 80*60*180cm
Power 220 V AC/50 Hz 4000 W
Protection grade Cabinet IP42, others IP65

Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser

Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser
Cems Continuous Emission Monitoring System So2 Nox O2 No No2 UV Analyser


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier