Cylinder Valve Self-Contained Positive Pressure Air Breathing Apparatus

Product Details
Customization: Available
Material: Brass, Stainless Steel
Transport Package: Paper Box
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
OEM/ODM Availability
Yes
  • Cylinder Valve Self-Contained Positive Pressure Air Breathing Apparatus
  • Cylinder Valve Self-Contained Positive Pressure Air Breathing Apparatus
  • Cylinder Valve Self-Contained Positive Pressure Air Breathing Apparatus
Find Similar Products

Basic Info.

Model NO.
KL99
Specification
133 x 70 x 36 mm
Trademark
KELISAIKE or OEM
Origin
Nanjing, China
Production Capacity
1000PCS

Product Description

 

Cylinder Valve Self-Contained Positive Pressure Air Breathing Apparatus 

Cylinder Valve Self-Contained Positive Pressure Air Breathing Apparatus
Feature:

  1.  The cylinder valve is an essential component of an SCBA.
    One side of the cylinder valve is connected with the gas cylinder with male thread, thread type is M18 x 1.5. The other side is connected with the SCBA pressure release valve with female thread, thread type is G5 / 8 "(14 teeth/inch) connector.
 
  1. The cylinder valve on the bottle had been called the first valve, set up with an over-pressure safety burst valve, when the gas pressure inside the cylinder pressure is 41.5 ~ 45 Mpa, the security protection film will explode, and the gas pressure relief quickly.
 
  1. Material of the cylinder valve: Brass / H59-1
  2. Working Pressure: 210bar/300bar;


Thread Specification:
 M18 x 1.5 thread connecting with gas cylinder

Technical Parameters:

1. working pressure: 30Mpa, 300bar
2. The burst pressure of the safety diaphragm: 41.5-45Mpa
3. When the air source pressure is in the range of 2-30Mpa, the output pressure is 0.6-0.9Mpa, and the output constant flow rate is 32-38L/min
4. When the output rises to 1-1.5Mpa, the safety valve opens to relieve pressure
5. When the pressure of the air source drops to less than or equal to 0.5Mpa, the alarm whistle will sound an alarm. As soon as the user is reminded that the air source will be exhausted, the hood should be removed